Skip to content

Case Study · Iron & Steel

EAF Delta High Emissivity Coating: Service Life Up 115% at an Integrated Steel Plant

Case study summary
IndustryIron & Steel
AssetPre-cast electric-arc furnace deltas
Customer or locationIntegrated steel plant
Products usedEmisshield ST-2 (patented)
Headline metric172 heats average
Secondary metric+115% vs upgraded refractory
Also measured1,560 to 1,650°C

Pre-cast ultra-low-cement deltas near the arc and scrap charge were cracking early from thermal shock, lasting about 40 heats, and only 80 after an upgrade to a spinel-containing castable. Coating the hot faces and electrode ports with Emisshield ST-2 raised average life to 172 heats, a 115% improvement, by shielding the surface through the initial heats so the castable could sinter properly.

01

What was the challenge?

Early cracking limited delta life and the plant wanted more longevity without redesigning the furnace.

02

What was applied?

Emisshield ST-2 on the deltas' hot faces and electrode ports, operating between 1,560 and 1,650°C.

03

What were the results?

MetricUncoated (upgraded castable)Coated
Average delta life80 heats (40 with original castable)172 heats
Life increase+115%
Early thermal-shock crackingRecurringEliminated
Maintenance and replacement intervalBaselineReduced; extended

The coating let the spinel-containing castable develop full strength, maximizing the refractory investment.

04

Why did it work?

The coated surface resists abrupt temperature spikes from arc flare during the first heats, the period when thermal shock does its damage, and re-radiates into the melt thereafter. See Production Increase, component life.

Next Step

Replacing deltas or roofs on a short cycle? Send us the furnace data and heat counts.