Skip to content

Quality · Test Data & Validation

Third-Party Test Data & Validation

Emisshield's core properties and plant results are validated outside Emisshield: hemispherical emissivity measured by a thermophysical properties research laboratory, ceramic fiber performance confirmed by independent testing, a university pilot furnace and a third-party coking study in petrochemical service, and a third-party audit of a coated aluminium furnace against an uncoated control. Key results are published on this site.

Technician holding up a coated test sample

01

Hemispherical emissivity and thermophysical properties, research laboratory analysis

The directional-integrated emissivity measurement that matters in an enclosure, and the source of the site's materials-values authority. Read the analysis

02

Third-party ceramic fiber testing

Six tests over one month across fiber types and temperatures with twelve thermocouples. Coated modules: shrinkage under 1% against 2 to 5% uncoated; continuous-duty limit roughly 150°C higher; cold face 6 to 10°C cooler. Case study

03

Ghent University IMPROOF pilot, EU Horizon 2020

Independent validation in a steam-cracking pilot furnace with uncoated preheat cells as control: 4.8% fuel reduction at steady state, refractory emissivity from ~0.4 to ~0.95 confirmed by independent lab tests, 7 to 12% projected at full scale by program modeling. Case study

04

Third-party process-tube coking study

A major petrochemical company's continuous coking study across feeds, with a coking index confirming a large reduction in coke formation on coated tubes. Case study

05

Third-party plant audit, aluminium

An independent auditor compared a coated melting-holding furnace with an uncoated control over six months of production data: roughly 9% less dross, 12°C higher melt temperature despite a heavier charge, and $645,000 more casting output over four months. Case study

06

Controlled comparisons against identical uncoated units

Apache Nitrogen (boiler 1 coated, boiler 2 uncoated, thermal imaging and daily heat-value data); India's largest aluminium producer (furnace 2 coated, furnace 1 uncoated, measured by an independent engineering firm); Redline Industries and a grey-iron foundry (coated ladles against uncoated control ladles). Case Study Library

07

Clemson University pilot kiln study

Core Property Test Results

The property envelope every formulation is tested against, with the verification behind each figure.

Core Property Test Results
PropertyResultVerification
Emissivityat least 0.96 (M-6), constant to 1,700°CIndependent laboratory analysis; Ghent pilot (~0.4 to ~0.95)
Adhesionat least 10,000 PSI (689 bar)Standard pull testing; verified under repeated thermal cycling
Thermal shock-236°C to 1,500°C in 3 seconds, no failureDocumented test protocol
Fiber shrinkage (coated)< 1% vs 2 to 7% uncoatedThird-party fiber testing; field-verified at Huntsman
ChemistryWater-based, non-hazardousProduct documentation

FAQ

Common Questions About Test Data

Can we get raw data for engineering review?

Yes. Datasets and full reports are available through Emisshield engineering or your distributor; NDAs are accommodated where needed.

Do you test per project?

Every project starts with a baseline; before-and-after fuel and temperature data against that baseline is how each case study is built, with an uncoated control unit where the plant has one.

Who performed the third-party audit?

An independent auditor commissioned by the aluminium producer; the audit examined six months of production data. Details on the case study page.

Next step

Engineering Wants the Reports?